Welcome to visit our website!

MEDICAL WATER MACHINE

Medical waterReverse OsmosisWater softenerStomatology Sterile waterEndoscope waterHemodialysis water

Water Softener water softing treatment machine

Water softener




>>>Operation principle

Automatic softener water system adopts the technology that using ion exchange to remove impurity such as calcium magnesium from water to make the water soften.The raw water can exchange the hardness composition of Ca2+ and Mg2+ with Na+ by sodium ion exchange resin, so that to absorb Ca2+ and Mg2+ ions and achieve water softening.

 

>>>Application

Widely used in steam generator, pulsating vacuum sterilizer, heat exchanger, central air conditioning cooling cycle¡¯s water softening.It can also be used in industrial, civil, food, pharmaceutical and electronic industries¡¯ water softening.

 

>>>Main characteristics

1> Automatic operations and procedures.

2> Stable operation ensureas softening effect.

3> Low cost, energy saving.

4> Compact structure, small standing area.

5> Directly connected with the tap water for deep softening.

6> Simple installation,it can be used when equipped with water and electricity.

 

>>>Technical parameters and Models

Model

Water output (L/H)

Resin content (kg)

Model and qty

(f¡ÁH¡Áset©L)

Salt box size and qty (f¡ÁH©L)

GPM

 

Working pressure range

(MPa)

HH-100

100

18

200¡Á890¡Á1

-----------

DN20

0.2-0.5

HH-500

500

50

250¡Á1370¡Á1

350¡Á750

DN20

0.2-0.5

HH-1000

1000

75

330¡Á1370¡Á1

350¡Á750

DN25

0.2-0.5

HH-2000

2000

120

400¡Á1670¡Á1

520¡Á1050

DN25

0.2-0.5

HH-4000

4000

150

500¡Á1750¡Á1

520¡Á1050

DN32

0.2-0.5

HH-6000

6000

200

600¡Á1950¡Á1

650¡Á1050

DN40

0.2-0.5

 

 

Item

Specs

Note

Water inlet pressure (Mpa)

0.2-0.4

0.3 is best

Salt consumption (g/mol)

160-250 max


Raw water hardness

8

Below 8 is better

Effluent residual hardness (mmol/L)

0.03 max


Water temperature (C)

2-38


Water consumption rate(L/H)

2%max of output

According to the using type.

Water output (L/H)

100-200


Resin type

001*7 type of strong acid cation exchange resin

The weight(kg)

35

According to the using type.

Size (mm)

480X280X1150

According to the using type.

Area (m2)

0.2

According to the using type.

Voltage (V/Hz)

220/50


Power (Kw)

3