Hypochlorous acid generator
Hheow Eow Electrolyzed Oxidizing Water Generator Producing Disinfectant to Kill Virus
>>>Working Principle
Adding electrolyte in raw water,the water will be electrolysis in through the diaphragm cell,then at the side of anode will generate acidic aqueous solution which main content is hypochlorite (HCIO) and last we will get EOW(Full name:Electrolyzed oxidizing water/Acidic oxidized electrolyzed water/Acid oxidiation-potential water).
Sodium hydroxide (NaOH) is formed from the cathode in strongly alkaline water.Acid water has function of strong oxidation so the water can kill microorganisms and sterilization.Alkaline water has function of anti - oil and protein and stripping emulsification so that it can remove organic matters.
>>>Main application
*(hand disinfection)
*(sterilize medical equipment)
*(removal of skin mucosa)
*(environmental surface disinfection)
*(disinfect tableware)
>>>Main characteristics
1> The system has PLC automatic program control and LCD touch screen operation.
2> The system has the function of displaying parameters,such as PH online,active chlorine content,electrolytic current and total working time so that it can monitor the specs of disinfector.
3> The system is with automatic cleaning function so that to prolong the service life of electrolyzer and stabilize the disinfectant water's using.
4> The alarm will sound when the electric current is too large or the raw water is not enough,so that to ensure the operation of the equipment and disinfectant.
5> The electrolytic cell automatically adjusts the weight of salt and adding salt with a precision metering pump.
>>>Main Model: HHEOW-1000 HHEOW-2000
Electrolyzed oxidizing water is a colorless transparent liquid, the main content is hypochlorite and it has chlorine smell.
Item | Specs | Note |
Model | HHEOW-1000 | HHEOW-2000 |
PH | 2-3 | 2-3 |
Oxidation reduction potential (ORP) (MV) | 1100 min | 1100 min |
Effective chlorine content (mg/L) | 50-70 | 50-70 |
Residual chloride ion (mg/L) | 1000 max | 1000 max |
Electrolyzed oxidizing water output (L/min) | 1 min | 2 min |
Power (V/Hz) | 220/50 | 220/50 |
Power (VA) | 550 | 750 |
Weight (KG) | 45 | 50 |
Size (mm) | 550x550x1550 | 550x550x1550 |
>>>Physicochemical property
(NOTE:ORP is an important parameter in the process of waste water treatment. It directly influences the quality and efficiency of the waste water treating.)